Celvaris Labs

Batch Verification Report

Batch verification and analytical summary for Ovagen.

Batch Code: P260112-M19762
BVR ID: OVAGP260112-M19762-BVR-20260608
Revision: 1.0
Research Use Only
Single Peptide · Batch Verified
Ovagen
Glu-Asp-Leu (EDL) · MW 375.37 g/mol · Lyophilised Powder
Purity
98.04%
HPLC
Water
3.78%
Karl Fischer
Mol. Weight
375.37
g/mol
Identity
Conforms
ESI-MS
P260112-M19762
Amber Vial · Filler-Free
BVR QR Code — Scan to verify batch
Scan to verify
Product
Ovagen (Glu-Asp-Leu (EDL))
Molecular Formula
C15H25N3O8  |  MW 375.37 g/mol
Intended use
Laboratory research and analytical reference applications only.
Batch & dates
Batch: P260112-M19762
Manufacturer catalog: M19762
QC release date: 2026-01-20
Form & amount
Form: Lyophilised peptide powder
Amount: As specified on Celvaris product label
Storage
Store in a cool, dry place away from light. Follow Celvaris storage guidance on the product label.

Analytical Results

The following analytical data was obtained from manufacturer testing of batch P260112-M19762. Celvaris has independently verified this data against our quality specifications.

TestMethodSpecificationResultStatus
AppearanceVisualWhite to off-white powderConformsPASS
IdentityMS (ESI)Consistent with structureConformsPASS
PurityHPLC≥ 98.0%98.04%PASS
Acetic acid contentHPLC≤ 15.0%2.12%REPORT
Water contentKarl Fischer≤ 7.0%3.78%PASS

Parameters not listed above (e.g. residual solvents, bacterial endotoxins, microbial limits) were not included on the manufacturer’s certificate of analysis for this batch and are therefore not reported here.

Storage & Handling

Storage Conditions:

  • Store at -20°C or below in original sealed vial
  • Protect from light and moisture
  • Do not freeze-thaw repeatedly once reconstituted
  • Recommended shelf life: 24 months when stored properly

General Laboratory Handling:

  • Handle using standard laboratory safety practices
  • Wear appropriate PPE (gloves, lab coat, safety glasses)
  • Use in well-ventilated area or fume hood
  • Avoid inhalation, ingestion, or skin/eye contact
  • Wash hands thoroughly after handling

Reconstitution:
Reconstitution methods, diluents, and working concentrations must be determined by qualified researchers according to their specific experimental protocols and institutional guidelines. Celvaris does not provide reconstitution instructions.

Additional Documentation:
For questions about this batch or to request additional information, contact [email protected]

All tested parameters conform to specification. No deviations noted.